What the code means
s is a heavier interference than p. Shrink or heavy press.
Formula
s6 at Ø20 mm
es / ei +48 / +35 µm
IT6 = 13 µm
Limits 20.035 / 20.048 mm
Ø20 s6
How we use this in the toolroom
On a die we shrink an s6 bush into an H7 housing when it will take side load. Measure both parts before you commit — interference at Ø20 is already tens of micrometres.
The numbers come from ISO 286 tables, the same charts Accurate Industries uses in Pune for dies, moulds and precision tooling. AlwaysReach is the browser version of that lookup — see our story.
Other shaft classes
Common hole/shaft pairings