What the code means
Heavier interference than H7/p6. Shrink or heavy press.
Formula
H7 at Ø20 mm
ES / EI +21 / 0 µm
IT7 = 21 µm
Limits 20.000 / 20.021 mm
Ø20 H7
H7/s6 at Ø20 mm
Interference fit. Clearance is hole minus shaft (negative = interference).
- Hole H7: 20.000–20.021 mm
- Shaft s6: 20.035–20.048 mm
- Maximum clearance -14 µm (always interference)
- Minimum clearance -48 µm (can be a press)
How we use this in the toolroom
Heavy-duty bushes and some locating hubs get s6. We measure both parts and calculate interference before heating. Guessing from a chart row is how housings crack.
The numbers come from ISO 286 tables, the same charts Accurate Industries uses in Pune for dies, moulds and precision tooling. AlwaysReach is the browser version of that lookup — see our story.
Other common fits
H7 at common diameters
Full type-ahead for every ISO class is on the ISO tolerance calculator. Convert the millimetre result with the unit converter.