What the code means
Interference / press. The shaft is oversize relative to the hole across the whole pair.
Formula
H7 at Ø20 mm
ES / EI +21 / 0 µm
IT7 = 21 µm
Limits 20.000 / 20.021 mm
Ø20 H7
H7/p6 at Ø20 mm
Interference fit. Clearance is hole minus shaft (negative = interference).
- Hole H7: 20.000–20.021 mm
- Shaft p6: 20.022–20.035 mm
- Maximum clearance -1 µm (always interference)
- Minimum clearance -35 µm (can be a press)
How we use this in the toolroom
Wear bushes in a punch plate are often H7/p6. If the customer later wants the bush out, plan an extraction groove — this fit is meant to stay.
The numbers come from ISO 286 tables, the same charts Accurate Industries uses in Pune for dies, moulds and precision tooling. AlwaysReach is the browser version of that lookup — see our story.