What the code means
Close running clearance. Hole never under nominal; shaft entirely under nominal.
Formula
H7 at Ø20 mm
ES / EI +21 / 0 µm
IT7 = 21 µm
Limits 20.000 / 20.021 mm
Ø20 H7
H7/g6 at Ø20 mm
Clearance (running) fit. Clearance is hole minus shaft (negative = interference).
- Hole H7: 20.000–20.021 mm
- Shaft g6: 19.980–19.993 mm
- Maximum clearance 41 µm
- Minimum clearance 7 µm
How we use this in the toolroom
This is the pairing we reach for when a punch or a pin must turn, or a cover must come off without a press. It is not a locational dowel fit — use h6 or k6 if it must stay put.
The numbers come from ISO 286 tables, the same charts Accurate Industries uses in Pune for dies, moulds and precision tooling. AlwaysReach is the browser version of that lookup — see our story.
Other common fits
H7 at common diameters
Full type-ahead for every ISO class is on the ISO tolerance calculator. Convert the millimetre result with the unit converter.